Specifications
- Throughput without ISE module
- 400 t/h
- Throughput of ISE module
- 320 t/h
- Maximum throughput (photometric + ISE)
- 560 t/h
- Light source
- LED
- Wavelengths
- 340 - 405 - 505 - 535 - 560 - 600 - 635 - 670 nm
- Photometric range
- -0.2 to 3.5 A
- Internal resolution
- 0.0001 A
- Measurement accuracy
- CV <1% at 0.1 A (for 340 nm, 405 nm and 505 nm); CV <0.1% at 2 A
- ISE module (optional)
- Electrode type: Na+, K+, Cl-, Li+ (optional); Sample type: Serum, plasma or urine; Sample volume: Serum: 100 μL / Urine: 200 μL
- Sample rotor capacity
- Up to 18 segments available (14 positions/segment)
- Barcode reader
- Yes
- Number of samples with barcode
- 9/segment
- Size of primary tubes
- Diameter 12 mm to 16 mm (max. height 100 mm)
- Sample well
- Diameter 13.5 mm
- Sample types
- Serum, plasma, urine, whole blood, cerebrospinal liquid, semen and biological fluid
- Dispensing mode
- Ceramic pump without maintenance
- Pipetting volume
- From 2 μL to 40 μL
- Pipetting resolution
- 0.1 μL
- Predilution ratio
- From 1:2 to 1:200
- Clot detector
- Yes
- Tip wash
- Inside and outside
- Volume of reagent bottles
- 20 mL, 60 mL
- Reagent rotor capacity
- 88 (44 bottles of 20 mL or 60 mL + 44 bottles of 20 mL)
- Cooled reagent
- Yes; Temperature range of refrigerator: From 6 to 11 °C (measured at 21 °C)
- Barcode reader (reagent)
- Yes
- Reagent volume R1
- 120 μL to 450 μL
- Reagent volume R2
- 10 μL to 300 μL
- Dispensing mode (reagent)
- Ceramic pump without maintenance
- Pipetting resolution (reagent)
- 1 μL
- Tip wash (reagent)
- Inside and outside
- Reaction volume range
- From 180 μL to 600 μL
- Number of wells
- 120
- Well material
- UV methacrylate
- Type of incubation
- Dry without maintenance
- Temperature
- 37.0 °C
- Temperature accuracy
- ± 0.2 °C
- Number of mixers
- 2
- Cuvette washing system
- 7 tips (2 for washing, 3 for rinsing and 2 for drying)
- Size (w., d., h.)
- 1200 x 720 x 1258 mm
- Weight
- 210 kg
- Mains voltage
- 115 to 230 V
- Mains frequency
- 50 or 60 Hz
- Electric power
- 500 VA
- Ambient temperature
- From 10 to 35 °C; From 10 to 30 °C (with ISE module)
- Relative humidity
- <85% without condensation
- Altitude
- <2500 m
- Water inlet
- External tank or mains water supply
- Water type
- Purified water type II
- Water consumption
- <14 L/h
- Bottle of high concentration waste
- 5 L
- Bottle of washing solution
- 5 L
- Operating system
- Windows® 10 64 bit (x64)
- CPU
- Equivalent to Intel Core i3 @3.10 GHz or higher
- RAM
- 4 GB
- Hard disk
- 40 GB or higher
- Monitor minimum resolution
- 1024x768
- Connector of serial channel
- USB
- Connectivity to LIS
- HL7 and ASTM protocols
- EC Directive-IVD
- 98/79/CE